# AI Data Center

5 related articles

Subscribe to updates
  1. arXiv

    AI data centers get decision-focused battery scheduling: mean minute-to-minute grid-import swings fall 71.70% and total cost 18.01%

    Power swings at AI data centers make grid-import smoothing hard, and with limited battery power and energy, forecast errors of similar size can lead to very different scheduling costs. BS-DFL writes the battery scheduling objective into training: a constraint-aware neural optimization layer first learns schedules without optimal-solution labels, then is frozen so scheduling costs and ramping risk train the demand predictor, and deployment needs no optimization solver. Over a 10,000-minute simulation using loads derived from measured AI workloads, BS-DFL cut the mean absolute minute-to-minute grid-import change by 71.70% and total scheduling cost by 18.01% relative to an MSE-trained predictor with a Gurobi solver, at an average decision time of 18.77 ms.

  2. arXiv

    Data center siting is locked in for years: one multi-objective RL agent lets planners retune water, power, carbon and reliability at inference time

    AI data center siting, power procurement and cooling are still settled once by static single-point scoring on day-zero numbers, though water, power and carbon drift over a 10- to 20-year asset life and commitments bind for years. The build-out becomes a tiered Markov decision process: strategic commitments occur only in discrete windows, carry switching costs and take effect after source-dependent lead times, dispatch uses only capacity that exists, and a preference-conditioned multi-objective agent returns a policy family steerable at inference time across cost, carbon, water and reliability. On real site data, preference conditioning gives a confirmed, steerable trade-off on both objective pairs across three commitment regimes, and lock-in covers the frontier more evenly.

  3. arXiv

    Reconfigurable optical links let AI data centers chase cheap, green power: 12.50% lower real-time grid cost and 2.724 points more local renewables

    Across five AI data centers with equal completed work and network resources, folding optical circuit switching into joint compute-electricity-network scheduling cut real-time grid purchase cost by 12.50% and raised local renewable utilization by 2.724 percentage points versus fixed optical operation.

  4. arXiv

    Pre-training can act as a grid knob: on 2048 GPUs, curtailment falls from 1.077 to 0.014 MWh

    In a 2048-GPU, renewable-direct-supply AI data center, embedding checkpoint waiting and feasible 3D-parallel GPU modes of LLM pre-training into day-ahead dispatch cuts operating cost by 20.02% and renewable curtailment from 1.077 to 0.014 MWh relative to fixed continuous training.

  5. Building the materials foundation for AI: Syensqo on advanced materials and AI as a two-way driver

    This MIT Technology Review Insights conversation produced in partnership with Syensqo records the views of Mike Finelli, Syensqo's chief technology and innovation officer and chief North America officer: AI is pushing semiconductors and data centers toward physical limits, which piles up more simultaneous requirements on advanced materials, and Syensqo is responding by developing materials for high-voltage data center architectures, advanced sealing materials for semiconductor manufacturing, and thermal-management solutions including direct immersion cooling fluids, while working with Microsoft on AI agents that digitally synthesize millions of candidate molecules, predict their performance through physics-based simulation, and rank them down to roughly a hundred candidates for laboratory