Skip to main content
Search

# Multiple Instance Learning

4 related articles

Subscribe to updates
  1. arXiv

    Ultrasound diagnosis stops chasing average accuracy: multi-query attention keeps heterogeneous evidence, training-time regularization lifts sensitivity to 0.874

    Patient-level ultrasound diagnosis has relied on a single attention bottleneck to aggregate multiple views, which dilutes sparse malignant cues and optimizes only global accuracy. C2LUE replaces that bottleneck with multi-query cross-attention, letting several learnable queries extract complementary morphological evidence, and adds a differentiable sensitivity-specificity geometric-mean regularizer during training. On biopsy-proven thyroid and breast ultrasound datasets, patient-level AUC reaches 0.932 and 0.936, with sensitivity rising to 0.874 and 0.876 at a moderate cost in specificity.

  2. medRxiv

    Ten microliters of unstained whole blood, imaged in 12 minutes: a three-class model flags sepsis at 100% sensitivity and 85.3% specificity

    Remoscope images 10 microliters of unstained whole blood into 20,000 pictures in about 12 minutes, and a three-class model separated sepsis from non-infectious critical illness and healthy controls in 29 critically ill adults, reaching 100% sensitivity at 85.3% specificity when tuned for rule-out.

  3. medRxiv

    Gated-attention multiple instance learning triages multi-center cervical cytology slides without per-cell labels, reaching 90.96% accuracy with MobileNetV2 and 80.43% balanced accuracy out-of-distribution with Xception

    The work presents a weakly-supervised, detection-free multiple instance learning framework that uses dual-branch gated attention pooling to make slide-level predictions on whole-slide cervical cytology images, treating each slide as a bag of local instance patches so that single-cell bounding boxes or pixel-level annotations are not required; evaluated on internal multi-center cohorts (SIPaKMeD, Herlev, and CRIC) and on the unannotated, out-of-distribution Mendeley LBC validation cohort processed via an unsupervised marker-controlled watershed pipeline, it reports that the lightweight MobileNetV2 backbone optimizes in-distribution multi-center accuracy (90.96% accuracy, 0.9800 ROC-AUC) while the higher-capacity Xception provides better out-of-distribution robustness under domain shift (80.

  4. Artificial Intelligence-Based Hypernasality Diagnosis Using CAPS-A-AM Rated Speech Samples in Pediatric Velopharyngeal Dysfunction

    In this prospective, single-center study, speech samples from 40 children aged 2 to 17 (including individuals with velopharyngeal dysfunction, conditions associated with VPD, and healthy participants) were collected during speech-language pathologist-guided evaluation with consensus CAPS-A-AM ratings, and mel spectrograms of high vowels /i/ and /u/ from sustained vowels, isolated words, and sentences were used to train logistic regression, an EfficientNet-V2-S attention multiple-instance-learning CNN, and a CNN-XGBoost hybrid for binary hypernasality classification at two CAPS-A-AM thresholds (absent 0 versus any hypernasality 1-4, and absent/borderline 0-1 versus mild-to-severe 2-4); multiple independent modeling approaches detected clinically rated hypernasality, with EfficientNet-V2-S a

You’re all caught up