Skip to main content
Search

# Position-Based Dynamics

1 related articles

Subscribe to updates
  1. arXiv

    Surgical tissue forecasts anchor to the last observation: median error ratio 0.912 across 12 clips, interval includes parity

    Surgical robots need to anticipate how instrument motion will deform tissue when visibility is interrupted, and prior differentiable physics simulation predicted absolute tissue positions, so reconstruction error, initialization, and simulation offsets left the whole surface persistently displaced. The forecast now anchors each tissue point to its last valid observation and predicts only the deformation induced by the known future tool trajectory, using mesh-free position-based dynamics with scene-specific rigidity, attachment, and grasp coupling. Across 12 surgical manipulation clips, the referenced forecast has a median within-clip error ratio of 0.912 against the persistence baseline, 95% interval 0.787–1.070, improving 8 of 12 clips, with the interval including parity.