Skip to main content
Back to timeline
arXivSource publication:

SEEM stumbles on one-pixel vessels: a 0.47M-parameter read-out adapter lifts 3 mm large-vessel Dice to 91.93%

Synopsis

The interactive segmentation model SEEM performs poorly on OCTA retinal vessels out of the box, reaching only 75.83% Dice on large vessels with a frozen encoder, and every candidate mask it can produce is read from the same quarter-resolution feature maps, too coarse for vessels one to three pixels wide. The Read-out Basis Adapter (RBA) adds 32 half-resolution basis maps at the read-out, which each candidate accesses through a zero-initialised projection, for 0.47M trainable parameters. On OCTA-500 3 mm large vessels, averaged over three seeds, it reaches 91.93% Dice and 85.16% IoU, 1.72 and 2.90 points above Conv-LoRA, with gains concentrated on thin vessels and edges and no significant difference on the FAZ.

Source-provided article image: RBA: A Read-out Basis Adapter for Parameter-Efficient Interactive OCTA Vessel Segmentation with SEEM
arXiv

Interpretation

The adaptation site for interactive retinal vessel segmentation moves from the encoder to the mask read-out: every SEEM candidate mask is a weighted sum of the same quarter-resolution feature maps, and RBA lets candidates draw on a set of half-resolution basis maps built per image. Earlier parameter-efficient methods such as LoRA, Conv-LoRA and AdaptFormer change what the encoder features contain, but not their quarter resolution or the way masks are read from them. On the 50 test images of OCTA-500 3 mm large vessels, RBA beat LoRA rank 16, Conv-LoRA and AdaptFormer on all 50; averaged over three seeds it reached 91.93% Dice against 90.22% for Conv-LoRA, and 85.16% IoU against 82.26%.

RBA has two branches: a read-out branch that builds 32 half-resolution basis maps from the image alone, and an encoder branch, a standard rank-1 LoRA, that supplies the information needed to tell arteries from veins. The read-out projection is initialised to zero, so the model starts exactly as pretrained SEEM and keeps SEEM's candidate generation and selection rule. On the OCTA-500 3 mm and 6 mm subsets and ROSE-O, the gain appears on large vessels, veins and arteries; 3 mm veins reach 90.49% against 88.87%, 6 mm large vessels 88.67% against 85.91%, and ROSE-O vessels 77.55% against 76.23%.

Perspective

Results cover the OCTA-500 3 mm and 6 mm subsets and ROSE-O, with clicks placed by simulation from the ground truth, the model selecting its own candidate at a fixed threshold of 0.5; all training and testing ran on one 8 GB laptop GPU.

Clicks come from error-driven simulation rather than real annotators, and the authors list clicks along vessel boundaries and a study with expert annotators as future work; multi-seed evaluation on the remaining targets and datasets, images from other OCTA devices, and ablations of basis count and resolution are also not yet reported.