Prompts can fix the answer while visual evidence collapses: training-free head damping cuts flip rate to 34.60%
Synopsis
Medical vision-language models cave to authoritative prompts, and prompt-level defenses can restore the right answer while visual evidence use still collapses in late fusion layers. HD-AS changes no parameters: it ranks attention heads by activation drift between neutral and biased prompts, then damps those heads' output projections at inference. On SLAKE, Qwen2.5-VL-7B's mean conditional flip rate falls to 34.60% versus 38.29% for contrastive decoding, with neutral-prompt accuracy held at 74.37%.
Interpretation
Sycophancy in medical vision-language models is located in internal representations, not only in the output vocabulary. Earlier mitigations mainly added prompt-level constraints or rewrote the input to push the model toward neutral answers. On SLAKE samples, prompt-level mitigation drops the visual attribution ratio to 0.049, so correcting surface behavior coincides with a collapse in internal use of image evidence.
The intervention touches a small set of attention heads and leaves model parameters untouched. Calibration compares hidden activations at the terminal decision position under neutral and biased prompts, scores each head by the median L2 drift, and keeps the top K heads as a sycophancy-sensitive circuit. At inference a forward pre-hook on those heads' output projections fires only at the terminal decision token and scales activations by 1−α; experiments use K=6, α=0.6 and a 40-sample calibration set.
Across four open-source medical vision-language models, HD-AS reports the lowest mean conditional flip rate within each model. The comparison covers system-prompt defense, text-neutralization rewriting and contrastive decoding. On SLAKE, Qwen2.5-VL-7B reaches 34.60% mean conditional flip rate versus 38.29% for contrastive decoding; Qwen2.5-VL-32B reaches 35.03% versus 36.17%; LLaVA-Med-7B reaches 39.48% versus 40.48%.
Perspective
Evaluation covers the binary yes/no subsets of SLAKE and VQA-RAD, with 355 SLAKE test samples and 239 VQA-RAD test samples, on open-source backbones including LLaVA-Med-7B, Qwen2.5-VL-7B, Qwen2.5-VL-32B and MedGemma-27B; GPT-4o appears only in behavioral audit tables and receives no activation intervention.
The authors note that evaluation is mainly limited to single-turn medical VQA, while real clinical dialogue involves longer context and multi-turn reasoning; identifying critical heads relies on offline calibration, and optimal hyperparameters may fluctuate with model scale and clinical domain; biased prompts are synthesized from counterfactual claims and coercion templates and do not fully reflect spontaneous clinical language, implicit bias or multi-turn persuasion.
