arXivSource publication:

Medical transfer stops leaning on layout: moving global attention to the feature axis lifts ultrasound Dice from 53.1 to 77.7

Synopsis

Medical transfer learning has long inherited spatial-attention backbones pretrained on natural images, yet layout priors do not survive shifts across scanners and modalities. FAD-ViT moves global modeling from spatial tokens to channel tokens and lets depthwise convolution handle local spatial extraction alone, strictly decoupling the two axes. Across 23 classification, segmentation and low-data tasks, the two axes are nearly tied from scratch, while identical ImageNet pretraining yields up to roughly three times the transfer gain on the feature axis, raising ultrasound segmentation Dice from 53.1 to 77.7 at about a quarter of the comparison's parameters.

Source-provided article image: Learning Features, Not Layouts: Feature-Axis Attention as a Transfer Prior for Medical Imaging
Figure 1 · arXiv

Interpretation

The axis of global attention is itself a lever for transfer design: placing global mixing on channel tokens rather than spatial tokens lets the same natural-image pretraining carry more usable structure into medical tasks. Earlier channel-aware backbones added channel attention to a backbone still dominated by spatial mixing, leaving the two axes entangled so the feature axis could not be measured alone; standard ViTs put all global modeling on spatial self-attention. Under matched tokenization, capacity and protocol, the feature and spatial axes perform essentially the same from scratch, while identical ImageNet pretraining yields a +15.1 Dice transfer gain on breast ultrasound for the feature axis against +4.3 for a capacity-matched spatial baseline, roughly a threefold difference.

The gain comes from the feature axis itself, not from a larger parameter budget or a stronger source task. Scaling the spatial baseline to ViT-B or using a pretrained convolutional encoder still yields only +5.7 and +6.0 Dice gaps, far below the feature axis's +15.1. The three backbones have comparable ImageNet-1K top-1 accuracy, with the feature axis ahead by only a few points, too little to explain Dice-level differences; a strict in-place axis swap on ultrasound, abdominal CT and cardiac MRI shows the feature axis converting pretraining into a larger gain on all three modalities.

Feature-axis attention shapes pretraining toward channel-correlation statistics, texture, intensity and co-activation, which recur across scanners and anatomy, whereas spatial-layout priors are largely invalidated by medical domain shift. Spatial-token attention instead learns object-layout priors specific to natural scenes, which are unstable in medical images. Centered kernel alignment between pretrained and from-scratch encoders stays higher at early and mid depth for the feature axis and collapses only at the last stage, while spatial-axis alignment decays monotonically; the authors read this as a corroborative correlate of the transfer gap rather than direct proof of feature reuse.

Perspective

The conclusion rests on 23 medical datasets and tasks, covering MedMNIST-2D classification, BUSI and dataset B breast ultrasound, BUSI plus 10 MSD-derived 2D segmentation tasks, and linear probing on 8 MedMNIST datasets at 1%, 10% and 100% labels. Segmentation experiments attach an identical U-Net decoder across encoders, classification is fine-tuned end-to-end, and linear probing freezes the backbone. The authors propose next steps of stronger pipelines such as nnU-Net, other architecture families and self-supervised pretraining.

From scratch, the axis swap costs only about 1 Dice and removing the spatial tail about 1 Dice, within seed variance, so the axis does not make the network intrinsically stronger and matters only after pretraining. Low-data linear probing is dataset-dependent: the feature axis leads on PathMNIST, OCTMNIST, PneumoniaMNIST and BloodMNIST but trails DINOv2 and ViT-S/16 on a few others. Grouping by modality shows the largest gain on ultrasound, less on MRI and least on high-contrast CT, with the near-saturated colon CT task marginally favoring DINOv2. The authors position the CKA alignment as a corroborative correlate of the transfer gap, not direct proof of feature reuse.